Quantcast
Channel: Andrew Bell's Communities Activities
Viewing all 5174 articles
Browse latest View live

Can't Open DXF files in Microstation or AutoCAD

$
0
0

Hi,

We get DXF files over that have been created in AutoCAD and in theory we should be able to open them in Microstation but 5% of the files that are sent over we can't seem to open in either.

I have tried to open in AutoCAD, Fusion 360 and Microstation but to no avail. I have also tried to add the file as a reference but that won't work either.

The error that comes up in Mircostation is 'Unable to open design file. Please contact your local site administrator or technical support provider for further assistance.' and it just crashes AutoCAD.

We can, however, open in it in QGIS, but can't extract the co-ordinates.

I have gone through every forum I can find but can't get any of the solutions to work.

Versions are:

Microstation - Microstation V8i (Select Series 3) [8.11.9.357]

AutoCAD - AutoCAD 2018

Many thanks!


How to solve the Program not Responding Error issue?

$
0
0

Hello,

I have an issue, last day when I was using the system it stops working or freezes for sometimes. The message of "Program Not Responding" appears on the screen. I restart the pc and uninstall the unwanted software programs and then again reinstall the software. But still, the system shows this message again and again. what should i do to solve this issue? should i have to visit Program not Responding Error for the solution? 

how to determine the version of an autocad DWG file

$
0
0

This may prove very helpful as time goes by....

To view the codes of a particular DWG file, open it within Notepad or other text editor program. The first text in the file is the code. 

MC0.0 - DWG Release 1.1 
AC1.2 - DWG Release 1.2 
AC1.4 - DWG Release 1.4 
AC1.50 - DWG Release 2.0 
AC2.10 - DWG Release 2.10 
AC1002 - DWG Release 2.5 
AC1003 - DWG Release 2.6 
AC1004 - DWG Release 9 
AC1006 - DWG Release 10 
AC1009 - DWG Release 11/12 (LT R1/R2) 
AC1012 - DWG Release 13 (LT95) 
AC1014 - DWG Release 14, 14.01 (LT97/LT98) 
AC1015 - DWG AutoCAD 2000/2000i/2002 
AC1018 - DWG AutoCAD 2004/2005/2006 
AC1021 - DWG AutoCAD 2007/2008/2009 
AC1024 - DWG AutoCAD 2010/2011/2012 
AC1027 - DWG AutoCAD 2013/2014/2015/2016/2017 
AC1032 - DWG AutoCAD 2018

CE U8 - Analyze cleanup don't distinguishes elements with fill on or off

$
0
0

Hi,

We continue to get duplicates where shouldn't be any (works the same in v8i).

1 - Draw a rectangle, a shape, a circle, whatever;

2 - Copy the rectangle (or your element) to the exact same location;

3 - Change one of the elements to get a fill shape;

4 - Run the Analyze\Design File Cleanup\General\Cleanup Actions with Select mode;

5 - Check the result.

I believe this analyze should take in consideration if the shapes have fill or not.

I don't want to get a positive result if I need two elements, one for the boundary and another for the actual fill.

Regards

"Move to Contact" Command - selected elements move in the opposite direction

$
0
0

I'm trying to use the "Move to Contact" command. The lines I'm trying to move, move in the opposite direction of the element I want to move them to. Any ideas?

Create drawing as one single entity

$
0
0

Microstation V8i (SELECTseries 2). I have a drawing in 2D that consists of multiple elements. I want to have the whole drawing as one entity so i can copy the drawing and paste it elsewhere as one drawing. Your help is appreciated.

upside-down text placement

$
0
0

When I place new text, it appears upside-down.   What setting needs to be changed to correct this?

Thanks for the attention. I want to know the command in the script file to rotate a cell before placing it in Microstation.

$
0
0

Thanks for the attention. I want to know the command in the script file to rotate a cell before placing it in Microstation.


Relative toggle missing from the Place Active Cell tool in MicroStation CONNECT Edition

$
0
0
 Product:MicroStation
 Version:CONNECT
 Environment:N\A
 Area:Cell
 Subarea:General

Problem

Why is the Relative toggle missing from the Place Active Cell tool in MicroStation CONNECT Edition?

           

               MicroStation V8i                               MicroStation CONNECT Edition

Solution

This capability for cell placement is an old concept and is in relation to using level numbers in your DGN files rather than level names. Level numbers are something that was replaced as a concept when the V8 series and DGN file format was initially released. The previous V7 DGN format was rejigged so it did not need to rely on a limited amount of levels or naming of those levels. So it was decided to remove the "Relative" option, in the CONNECT Edition, from the Place Active Cell tool to limit the availability but not to stop this capability from being performed as it is still required if V7 DGN file format is in use.

To be able to use this option from MicroStation CONNECT Edition you will have to use the key-in that will still be available in future versions.

PLACE CELL RELATIVE

The following detail supplied in the V8i help documentation may assist in explaining why this toggle was originally used.

Relative

Point cells are always placed on the Active Level.

But if the active cell is a graphic cell and Relative is:

  • On — the Number of the level(s) on which elements in the graphic cell resided when the cell was created determine the level(s) on which the graphic cell is placed, as follows:
    • The graphic cell is placed on a level(s) relative to the Active Level's number. For example, consider a graphic cell that was created with elements on levels with the numbers 5, 7, and 8. If the Active Level's number is 1, the cell is placed on levels with the numbers 1, 3, and 4. If the Active Level's number is 45, the cell is placed on levels with the numbers 45, 47, and 48.

    • However, if the graphic cell has elements on any level whose number is not an attribute of a level in the DGN file, the placement operation fails.

  • Off — the Name of the level(s) on which elements in the graphic cell resided when the cell was created determine the level(s) on which the graphic cell is placed, as follows:
    • If the graphic cell elements reside on a level, and a level with the same name exists in the DGN file, the elements in the graphic cell on that level are placed on the corresponding level in the DGN file, even if the level settings are not the same.

    • If a level with the same name does not exist in the DGN file, the level is copied from the cell library into the DGN file. However, any elements in the graphic cell on the Default level in the cell library are placed on the Active Level.

See also

Other language sources

 Original Author:Bentley Technical Support Group

MicroStation CONNECT Edition Update 8 stopped working when Windows 10 Spring Creators Update was installed. Someone else happened to him?

$
0
0

MicroStation CONNECT Edition Update 8 stopped working when Windows 10 Spring Creators Update was installed. Someone else happened to him?

Resolved issues in MicroStation CONNECT Edition Update 9, 10.09.00.23

$
0
0
 Product(s):MicroStation
 Version(s):10.09.00.23
 Environment:N\A
 Area:FAQ
 Subarea:N\A

Resolved issues in MicroStation CONNECT Edition Update 9, 10.09.00.23

This is the list of the resolved issues for MicroStation CONNECT Edition Update 9, 10.09.00.23

See HTML Table below 

Defect NumberDescription
793722Added GCS EPSG:5681 to EPSG:5685
706075Resolved issue with specific DWG file delayed during open
797279Rationalized BeTA2010 German GCS
807476Resolved issue with logical value displays as Master in Level Manager with empty levels from DGNLIB
637845Resolved Keyin issue with export googleearth [Filename] that results in Save File dialog pops up
696939Fixed issue with Raster attachment boundary should not be considered for flood calculations
700662Implemented CGCS2000
763172Resolved issue with WMS image does not display when you switch from Default to Sheet Model view
808509Resolved issue with German BWTA2017.gsb file supporting reprojection from DHDN to ETRS89
819789Rationalize Czech coordinate systems
820544Resolved issue with Problem with the display of 3MX Model
854346Resolved issue with incorrect interpretation of WKT/PRJ file for Czech coordinate system
820996Fixed specific issue with copy PDF as OLE
854630Resolved issue with allowing unsimplified mesh
322752Fixed issue with specific Accudraw with Measure Area by points method
712034Resolved issue with By level assigned text color changes after changing text style through Properties
820173Optimized MS_WORKSETMISMATCH_ALERT_EXCLUDE_VARS_WORKSPACELEVEL when defined to generate the list of files from Mapped drives
855521Resolved CadWorx Object Enabler display issue

See Also

Other language sources

 Original Author:Maria Garcia

Resolved issues in MicroStation CONNECT Edition Update 8, 10.08.00.37

$
0
0
 Product(s):MicroStation
 Version(s):10.08.00.37
 Environment:N\A
 Area:FAQ
 Subarea:N\A

Resolved issues in MicroStation CONNECT Edition Update 8, 10.08.00.37

This is the list of the resolved issues for MicroStation CONNECT Edition Update 8, 10.08.00.37

See HTML Table below

Defect NumberDescription
744331Resolved issue with mesh element's indices that are incorrectly created in DWG
709039Resolved issue with converting specific .LAZ does not maintain Coordinate System
567368Resolved issue when converting specific E57 to .POD
750329Fixed issue with DWG Text from Section Block not Aligning correctly
718050Resolved crash while importing specific keyin based text file
717310Fixed issue with text using key-in strings for Text Attributes that would cause specific crash in MicroStation CONNECT Edition
747824Fixed issue with Editing the Thermatic Height Display Style with ESC closes dialog and MicroStation becomes unresponsive/td>
746738Resolved specific issue with fence clip and reference with offset/td>
727233Resolved issue with compile after including Contraint3dElementAPI.h
749828Fixed issue with creating polygons with sides not orthogonal between them
752445Resolved issue with creating a new material in an empty file where the palette name cannot be changed.
775584Fixed issue with element section using crossing will select masked reference elements.
771306Fixed issue with PDF that doe not display a correct size when the scale is other than 1
779214Fixed issue with DWG with annotation scale applied to the viewport displays differently in MicroStation than in AutoCAD
773653Decreased the time to display properties dialog when a cell is selected in the cel library dialog with the properties dialog opened
764291Fixed Cubic mapping not being correct in render on mesh
744567Resolved issue when selecting elements in master, elements in clipped reference are selected as well
773320Added missing DSpiral2dBase.h file in SDK
723706Resolved issue with Sheet Border when created in 2D Design model does not remain associated with sheet in specific file
752683Fixed issue when copying a clipped self reference file crashes MicroStation
746831Resolved MicroStation crash after applying display rules with patterns and selecting and deselecting elements
784862Fixed Vertical Reprojection incorrect when converting from Geoid to Geoid with different datums.
785432Fixed Microstation crashs when selecting favourites when place text field
765447Resolved issue with Configuration Variables dialog displays duplicate entries for _USTN_WORKSETSDGNWSROOT
765448Resolved issue with Configuration Variables dialog displays duplicate entries for _USTN_WORKSETDGNWS
730520Decreased time to apply variarations of Parametric cell
691510Resolved issue with specific external material table will not be transfered to a copied model.
372770Fixed Place Note tool the text line weight is 0 regardless of the active line weight or the text style.
762837Resolved issue with specific MicroStation crash on startup with custom VBA
792843Resolved issue with Raster Line Styles are not being honored when enabling on/off the Line Style in the View Attribute dialog.
737438Fixed MicroStation crash while viewing the specific attached SP3D i-Model
786529Fixed issue with specific DWG Text for Cell blocks not aligned correctly
747381Fixed issue with Reference using saved views are shifted on file open with specific file.
676990Resolved issue with Text node not appearing after changing properties.
780401Checking if a shape element is Planar in VBA gives inconsistent results
759751Resolved VBA issue withsAssigning new TextStyle to Textelement in TextNode raises runtime error
744132Fixed VBA attachment object invalid after executing an Undo of previous attachment move
694656Fixed issue with light preview wont reflect color change immediately required to regenerate preview
710610Resolved issue when opening a specific file with a bitmap image causes crash
765449Fixed issue with DGNWS is not being written to when relocated using _USTN_WORKSETDGNWS
746438Fixed issue whith DWG Referenced Note Rotates Text When Using "Use Annotative Scale"
755156Resolved issue with FBX files do not display texture
797532Resolved issue with specific file where Bing Maps displays at incorrect position
797279Rationalize BeTA2010 German GCS
706075Resolved issue with specific DWG File causing hang on open
807476Fixed issue with logical value displays as Master in Level Manager with empty levels from DGNLIB

See Also

Other language sources

 Original Author:Maria Garcia

FAQ - MicroStation

$
0
0

MicroStation CONNECT Edition Update 8 ReadMe

$
0
0

To view the readme, please extract the zip file and then open the index.html file.

MicroStation CONNECT Edition Update 9 ReadMe

$
0
0

To view the readme, please extract the zip file and then open the index.html file.


CONNECT Advisor?

$
0
0

What does this mean - "Unable to find relevant content"? What content should there be?

Configuration Explorer is not showing any installed CONNECT applications

$
0
0
 Product(s):Bentley Configuration Explorer
 Version(s):10.00.00.11
 Environment:N\A
 Area:Configuration
 Subarea:General

Problem

When launching the Bentley Configuration Explorer the Process Configuration dialog opens but it is not showing any applications to choose from despite various CONNECT applications being installed.

Solution

To resolve this close the Process Configuration dialog and load the required applications using the Configuration Explorer dialog with the following steps :

1. On the Configuration Explorer dialog select 'Tools' followed by 'Application Manager'.

2. On the Application Manager dialog select 'Add' to choose from a list of available installed CONNECT Edition applications. Alternatively, drag & drop the applications shortcut from the Windows Start menu.

3. Choose the application (ie. MicroStation CONNECT Edition) from the available list and select 'Add'. If required hold the CTRL key down to select multiple applications or add them individually later.

4. Select 'OK' on the Application Manager dialog when done adding applications

5. From the Configuration Explorer dialog select 'Process' to reopen the Process Configuration dialog and the Application(s) selected earlier should now be available.

See also

Other language sources

 Original Author:Carl Myhill

How can I purchase software Microstation v8i series 3 ?

$
0
0

I’m trying to buy the Microstation v8i series 3 

Connecting round duct to 5 sided duct

$
0
0

I am trying to connect a round duct to a 5 sided polygon duct using Microstation.  Can this be done?

Select orphan cells

$
0
0

How to select orphan cells (cells without name)? Selectby allows to select cells by name but not cells without name as leaving cellname empty it finds all cells.

Viewing all 5174 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>