Quantcast
Channel: Andrew Bell's Communities Activities
Viewing all 5174 articles
Browse latest View live

Is there an easy way to fix the resolution units with a batch process?

$
0
0

I have a project that was exported from AutoCAD where it set the Resolution units and Working Units to feet and I need them to be in US Survey Feet. I know I can run the Set Units Key-in to change the working units but is there any other way to change the Resolution units so I don't have to do it manually for every model? I'm currently using V8i, but I have Connect available if that would make any difference. 


Preparing Layout in Microstation connect : is there any way to import legends automatically?

$
0
0

Microstation connect is having a separate section called sheet space for layouts. is there any possibility of importing legends in a definite format to the layout as a graphic or a part of drawing. ArcGIS is having a separate wizard for the import. is there any option to import the legend as like in arc GIS or any other similar way. Kindly suggest me so that it will be useful in sheet space.

Is there a component library to download site equipment

$
0
0

Is there a download area that others can add component to for sharing?

Microstation Connect 6 & 9 stops running.

$
0
0

Microstation Connect 6 & 9 stops running when I try to open it. I have unloaded and reloaded program but it still stops running. What is the fix?
Thanks, Scott

MicroStation Connect and MicroStation SS3

$
0
0

Will MicroStation CONNECT Edition (Full) x64 Udate 9 work along side MicroStation V8i (SELECTseries 3) 08.11.09.459 [32 bit installation]. In other words, can they both be installed on the same PC and run independently?

MicroStation CONNECT Update 9.1 fails to start

$
0
0

After updating to MicroStation CONNECT Update 9.1, I see this message in a text window as MicroStation starts: MDL Loader: Could not load application ustnvba

MicroStation halts once the backstage is shown.  It won't proceed to a work session.  This is a default vanilla installation of MicroStation.  Windows Pro v1709.

Resolution

I uninstalled Update 9.1 and reinstalled Update 9.0.  MicroStation CONNECT is working once more.  An inconvenient experience.

URGENT: How to convert DGN. file to DWG. using plot / batch converter / publish ?

$
0
0

Can anyone suggest me the best possible way to change .DGN file to .DWG in one batch ? whether using plot / batch converter / publish etc. 

Regards.

Microstation CONNECT Trial - Failed when starting

$
0
0

Hi all

I've downloaded Microstation Trial (ms100600102en_updt6.exe), installed it.

But when I start it, it stops with a gray screen. No error message.

when trying to connect with Connection Client, I get the message "Not associated with an organization". But I have an account (just me, no organization, since I am testing it).

Hardware: Microsoft Surface Book 2

Any help appreciated

Johannes


Configuration Explorer query

$
0
0

I have installed and run the CONNECT version of Configuration Explorer which shows 4no. errors. How do I find what the errors are? I can't see anything obvious that lists these in more detail.

Bentley plugin for Revit 2018

$
0
0

Hello,

I would like to know if development of Bentley plugin will contionue for Revit 2018, or what is the plan for development in Revit for next versions. I was using Bentley for export (producing i-models) to (i.dgn) in Revit 2017.

Thank you in advance for an answer.

Dominik Krajíček

Unable to create temporary file for Undo

$
0
0
 Product:MicroStation
 Version:V8 2004, XM, V8i, CONNECT
 Environment:N\A
 Area:Drawing Aids
 Subarea:General

Problem

When performing the Undo command the following error message is being displayed:

Unable to create temporary file for undo: C:\....\....\Temp\msundo. Undo currently disabled, changes made to the file will not be able to be undone.

While editing any open file in MicroStation it is not possible to undo any changes made to this file.

Solution

Check that there is write access to the temp directory listed in the information message being displayed. This is where MicroStation writes the undo changes. i.e. msundo1, msundo2, etc. If this user logged does not have write access to this file or folder this message will be displayed and they will not be able to Undo any changes made to their files.

See Also

Other language sources

 Original Author:Erik Lofgren

How to remove a default Menu Bar entry?

$
0
0

Trying to modify the Menubar to remove Tools : Product Add-Ins : Activate Descartes

Anyone know what (if any) dgnlib is used to control the menubar?

How to Change the names of your View Groups

$
0
0
 Product:MicroStation
 Version:V8i, CONNECT
 Environment:N\A
 Area:View
 Subarea:View Groups

Problem

I use View Groups in my project and I want to change the names of those View Groups.

Solution

1. Go to the Manage View Groups dialog box by clicking the following icon at the bottom of the design window.

2. Click 'Edit View Group Properties' by clicking on the following icon in the Manage View Groups dialog box.

3. A small window will appear with the option to edit the Name and the Description of the View Group. Change the name to what you would like. Click OK and the name will automatically change.

See also

Other language sources

Deutsch , Français

 Original Author:Erik Mendoza

Can not delete Model From List

$
0
0

I am trying to delete a duplicate model. Basically it doesn't show in the list of model (REFER IMAGE 1)  but it shows in where you can switch between the models (Bottom left drop down menu, next to views, REFER IMAGE 2). How can I delete that model which does not exist at all.

IMAGE 1

IMAGE 1

IMAGE 2

IMAGE 2

some questions regarding dimension association in MS V8i

$
0
0

Hello All,

I have some questions regarding MS V8i dimension association:

1. For associated dimensions, if I delete the source elements, the dimension line will be dotted. Is it possible to disable such function?

2. For associated dimensions, how to remove the association? And how to remove association for all? Is there keyin/MVBA way?

3. For associated dimensions which has lost the source element and is dotted already, how to change them in solid line?

4. For associated dimensions which has lost the source element and is dotted already, it it possible to print them in solid line?

5. How to reassociate dimensions? I tested on a dimension which connect to the end point of a line, OK. But if it connect to an end point and the middle point, failed. In another word, reassociate dimension function works one some key point only?

6. Can reassociate dimension function allow some tolerace? For example, it is not on the exact end point, but very close to the end point.

7. How reassociate all dimensions which can be reassociated?  Is there keyin/MVBA way?

Thanks a lot!


Numerical Key Pad

$
0
0

I have just upgraded from Microstation V8i to Connect.
In V8 you can enter commands i.e. 34 (rotate) using the numbers along the top of the keyboard and/or the numerical keypad on the right hand end of the keyboard. Now in Connect I cannot use the numerical keypad as described, however I can use the numerical keypad to enter line distances etc.
I have played with the obvious num lock key.
User > Preferences > Position Mapping > Position Mapping is ticked...
Is there a setting which allows the use of the numerical keypad as described above?

MicroStation CONNECT Update 9.1 fails to start

$
0
0

After updating to MicroStation CONNECT Update 9.1, I see this message in a text window as MicroStation starts: MDL Loader: Could not load application ustnvba

MicroStation halts once the backstage is shown.  It won't proceed to a work session.  This is a default vanilla installation of MicroStation.  Windows Pro v1709.

Resolution

I uninstalled Update 9.1 and reinstalled Update 9.0.  MicroStation CONNECT is working once more.  An inconvenient experience.

SIG: Reference Methods and Querying the Business Data - MicroStation

$
0
0
This MicroStation Special Interest Group virtual workshop focuses on Reference Methods and Querying the Business Data and will cover how to incorporate existing utility, drainage, and geographic data – obtained in a variety of different formats – and display it as background information in the context of a proposed roadway design. You will learn how to: Control display of reference files Leverage existing data obtained in different CAD formats Set location of referenced drawings using geographic coordinate systems Edit an attached reference Display reference data at the correct size View and query geographic data Apply Element Templates This SIG one-hour workshop will include a technology presentation and time to share questions. Attendance is complimentary.

SIG: Reference Methods and Querying the Business Data - MicroStation

$
0
0
This MicroStation Special Interest Group virtual workshop focuses on Reference Methods and Querying the Business Data and will cover how to incorporate existing utility, drainage, and geographic data – obtained in a variety of different formats – and display it as background information in the context of a proposed roadway design. You will learn how to: Control display of reference files Leverage existing data obtained in different CAD formats Set location of referenced drawings using geographic coordinate systems Edit an attached reference Display reference data at the correct size View and query geographic data Apply Element Templates This SIG one-hour workshop will include a technology presentation and time to share questions. Attendance is complimentary.

Shared Cell Update

$
0
0

It would be good if we could simplify the shared cell definition update to a right click>update from library as per element templates, materials, multi-lines etc etc... 

The current workflow is, to say the least convoluted, 

- open the dgn file (in which you want to replace the pattern cell)
- open Element>Cells
- detach an attached cell library
- make sure the option Use Shared Cells is checked
- activate and place the shared cell that is used in the pattern (so that there is at least one instance in the file)
- uncheck the option Use Shared Cells
- attach the cell library that contains the replacement cell
- select/activate the corrected cell (click the placement button in the Cell library dialog)
- activate the replace cell command
- set the following:
method: Replace
mode: Global
- identify and accept the visible shared cell
- the pattern cell should be replaced now.
- update the view
- the pattern cell should now be updated